PE-RT Type II pipes

Share on FacebookShare on Twitter

PE-RT (Polyethylene of Raised Temperature resistance) pipe is a medium-density polyethylene pipe produced using a special molecular design and synthesis process. By copolymerization ethylene with octene and controlling the number and distribution of side chains, a unique molecular structure is achieved, enhancing the heat resistance of the pipe.

PE-RT pipes can withstand temperatures up to 60°C, thanks to the presence of short octene side chains that prevent the polyethylene molecules from crystallizing into a single sheet.

This structure maintains the pipe’s flexibility, high thermal conductivity, and chemical inertness while improving its pressure resistance, making it suitable for long-term hot water transport below 60°C. Additionally, PE-RT pipes retain excellent low-temperature flexibility,impact resistance, and are environmentally friendly, being non-toxic, odorless, and recyclable. They can also be joined using heat fusion, simplifying installation and maintenance.

Differences Between PE-RT and PE-RT Type II Pipes

1、Raw Materials:

○ PE-RT pipes are made by copolymerization medium-density (MDPE) or linear low-density polyethylene (LLDPE) with octene.

○ PE-RT Type II pipes are made by copolymerization high-density polyethylene (HDPE) with hexene or butene.

2. Molecular Density:

○ PE-RT Type II pipes have a molecular density between 0.942 and 0.96, which is higher than that of standard PE-RT pipes (density below 0.942). This higher density results in greater hardness.

3. A common on-site method to differentiate the two types involves heat fusion welding.

Under the same temperature and heating time, PE-RT Type II pipes will have smaller,harder weld beads compared to standard PE-RT pipes, which have larger, softer weld beads.

4. Pressure and Heat Resistance:

○ PE-RT pipes are highly susceptible to creep at temperatures around 70°C,making them unsuitable for high-temperature systems. They are best used for low-temperature hot water systems below 60°C.

○ PE-RT Type II pipes offer greater pressure and temperature resistance,suitable for hot water systems operating between 70°C and 95°C. Their performance remains stable even under high temperatures.

5. Application:

○ PE-RT pipes are typically used in small-diameter underfloor heating systems and other low-temperature applications, such as DN16, DN20, and DN25 piping.

○ PE-RT Type II pipes, with their superior resistance to temperature, pressure,and corrosion, are used in urban heating, hot spring water transport, hotels,hospitals, schools, airports, chemical plants, oil and gas industries, and renewable energy systems.

Characteristics of PE-RT Pipes

● Lightweight and easy to transport and install.

● Excellent flexibility, allowing for coiling and bending, which reduces the need for fittings and lowers installation costs.

● Stress relaxation at bends, preventing “spring back” and facilitating easier installation.

● Low friction loss, providing 30% greater fluid transport capacity compared to metal pipes of the same diameter.

● Superior low-temperature resistance, allowing construction even in winter without needing to preheat the pipe.

● High chemical resistance, non-corrosive, and long-lasting.

● Suitable for use in environments with a working temperature of 70°C and a pressure of 0.4 MPa, with a service life of over 50 years.

● Free of toxic additives, with smooth inner walls that resist scaling and bacterial growth, making them safe for drinking water.

● Impact resistance is five times higher than that of PVC-U pipes.

● Excellent heat and pressure resistance, with reliable, leak-proof connections through heat fusion or mechanical joining.

● Environmentally friendly, with recyclable materials.

● Can be used safely under high-temperature conditions for over 50 years.

● Outstanding resistance to frost and impact, making them ideal for winter construction.

● Non-toxic, odorless, and suitable for safe drinking water applications.

● Available in coil form for flexible use.

● Recyclable heat fusion materials offer environmental benefits.

Special Features of PE-RT Pipes

1. Durability: PE-RT Type II pipes have significantly better heat and pressure resistance compared to standard PE-RT pipes, ensuring a longer service life.

2. Flexibility: PE-RT pipes are highly flexible, making them easy to bend and ideal for underfloor heating installations.

3. Safety and Convenience: The unique properties of PE-RT Type II pipes ensure safer connections and easier repairs.

4. Environmental Benefits: Both types of PE-RT pipes are environmentally friendly.

PE-RT Pipe Heat Fusion Welding Process

For heat fusion socket welding, follow these key steps:

1. Control the welding machine temperature: Set the temperature between 240-260°C.

2. Speed: Ensure quick and precise insertion of the pipe and fitting into the mold at the moment of extraction from the welding machine.

For larger diameter PE-RT pipes, a butt fusion process is recommended:

1. Fix the pipe: Secure the pipe and fitting in the welding machine, ensuring they are aligned on the same plane.

2. Plan the pipe ends: Clean and plane the ends before heating.

3. Heat and weld: Preheat the machine to 210-220°C, then heat the pipe ends. The melting time depends on the wall thickness. After heating, apply pressure to join the ends and hold until they cool.

4. Inspect the weld: After cooling, inspect the weld for uniformity and strength.

Choosing the Right Pressure Rating

When the water temperature is between 50-70°C, use S5 class 1.25 MPa series pipes and fittings. For temperatures between 70-85°C, S4 class 1.6 MPa pipes are recommended.

For diameters between DN20-110, use heat fusion socket welding, and for DN110-500, use butt fusion welding.


What is PE-RT Pipe


Electrofusion Welding in PE-RT Pipe Networks

Electrofusion welding is complex and requires skilled operators to avoid issues like cold welding or leaks, which could compromise safety. Due to its complexity and cost, it is generally used only in special situations where traditional welding methods are impractical.

For summary, PE-RT pipes, made from a special medium-density polyethylene, offer excellent flexibility, heat resistance, and durability, making them ideal for hot water systems below 60°C. They are environmentally friendly, recyclable, and maintain their performance even in low temperatures.


PE-RT Type II pipes, with higher density and better pressure and heat resistance, are suitable for more demanding applications, such as urban heating and industrial hot water systems. Both types of pipes can be easily installed using heat fusion welding, ensuring reliable, leak-proof connections.

Related Posts

Where to check UK49-Results
General

Where to check UK49-Results

Asia’s Midshore Financial Centres Are Reshaping Cross-Border Capital Flows
General

Asia’s Midshore Financial Centres Are Reshaping Cross-Border Capital Flows

How to Turn Your Favorite Pet Photos Into Meaningful Home Décor
General

How to Turn Your Favorite Pet Photos Into Meaningful Home Décor

Algorithmic FUE Explained: How Structured Planning Is Changing Hair Transplantation
Health

Algorithmic FUE Explained: How Structured Planning Is Changing Hair Transplantation

Few areas of cosmetic surgery have been reshaped by technique and technology as much as hair restoration. Extraction tools have become finer, magnification has improved, and planning has moved from freehand estimates toward structured, protocol-driven work. Yet patients who read about "advanced" or "revolutionary" methods often struggle to separate genuine clinical progress from marketing language. This guide explains how modern FUE works, what it means to plan a transplant algorithmically, how Algorithmic FUE fits into that picture, and how to judge any technology claim critically. From strips to follicular units: a short history For decades, the standard approach to hair transplantation was strip surgery: a thin band of scalp was removed from the back of the head, dissected under microscopes into follicular units, and implanted into the recipient zone. The method works and remains in use for selected cases, but it leaves a linear scar and requires a longer healing period. Follicular Unit Extraction (FUE) emerged as an alternative in which individual units of one to four hairs are removed directly from the donor area using a small circular punch. The scars are tiny and dispersed, which allows patients to wear short hair without a visible line. As tools and training improved, FUE became the dominant technique worldwide. Its flexibility also created a challenge: because the method can be adapted in many ways, results depend heavily on the surgeon's judgement and discipline. What "algorithmic" planning means in practice In everyday language, an algorithm is simply a defined sequence of decisions. Applied to hair transplantation, it means that the key choices of the operation, where grafts are taken from, which grafts go to which zone, at what angle and density they are implanted, follow a documented logic rather than being made ad hoc during surgery. A structured plan typically addresses several questions in a deliberate order: The value of a structured method is consistency. When each case is reasoned through the same sequence, it is less likely that an important variable will be overlooked on a busy day, and it is easier to review and teach the approach to other physicians. Algorithmic FUE at Hairmedico Clinic Algorithmic FUE is the proprietary technique name used at Hairmedico Clinic in Istanbul, founded and led by Dr. Arslan Musbeh. It describes the clinic's protocol-based approach to planning graft extraction and implantation, and it is applied within a one-patient-per-day schedule so that the surgeon can supervise each step of the procedure. Dr. Arslan Musbeh graduated from Odessa State Medical University in 2000, is an active member of FUE Europe, and has taught as a faculty instructor on the DIU Calvitie programme at Université Claude Bernard Lyon 1 since 2019. The clinic reports more than 4,500 procedures in total, with more than 3,000 performed personally by Dr. Musbeh. As with any proprietary method, patients should treat the name as a starting point for questions, and ask Dr. Musbeh during the consultation to explain exactly how the protocol applies to their own donor area and hairline. The anatomy of a well-planned FUE procedure Understanding each stage helps patients ask better questions and recognise what a careful operation looks like. Diagnosis and design. The surgeon examines the scalp, evaluates the stability of the hair loss and measures donor density. The hairline is designed with the patient, taking face shape, age and the likely future pattern of recession into account. The design should be reviewed and approved before the operation begins. Extraction. Using a fine punch, follicular units are removed from the donor area. The aim is to harvest evenly and to avoid creating zones that look thin once the hair is cut short. The depth and angle of the punch must match the direction of the follicle, otherwise there is a risk of transection, in which the follicle is cut and cannot grow. Sorting and storage. Grafts are counted, grouped by the number of hairs and kept in a suitable solution while they are outside the body. Short, controlled storage times support survival. Recipient site creation. Small channels are created at a predetermined angle, direction and depth. This stage is decisive for the natural appearance, as it fixes how each graft will sit and how the hair will grow. Implantation. Grafts are placed into the channels with attention to their orientation. Single-hair units go to the leading edge of the hairline, and multi-hair units are positioned behind it. Aftercare and review. The patient receives written instructions and a schedule for reviews during the first year. Tools and technologies: what they do and what they do not...

Read more
Where to check UK49-Results

Where to check UK49-Results

Immigration Bonds in Oak Cliff: Understanding the Process and Your Legal Options

Immigration Bonds in Oak Cliff: Understanding the Process and Your Legal Options

Commercial Electrician Pensacola, FL: Finding the Best Electrical Contractor for Your Business

Commercial Electrician Pensacola, FL: Finding the Best Electrical Contractor for Your Business

Private Chauffeur Transportation For Miami And Orlando Travel

Private Chauffeur Transportation For Miami And Orlando Travel

Are you looking for ways to earn money on Cashout Fridays
game

Are you looking for ways to earn money on Cashout Fridays

Discovering the World of Online Gaming Platforms: Featuring Oddigo
General

Discovering the World of Online Gaming Platforms: Featuring Oddigo

General

PE-RT Type II pipes

Samsung’s Marketing Strategy
Marketing

6 Lessons to Learn from Samsung’s Marketing Strategy

Auto-Run Python Program on Raspberry Pi Startup
Tech

Auto-Run Python Program on Raspberry Pi Startup

No Result
View All Result
  • Automotive
  • Business
  • Career
  • Economy
  • Education
  • Entertainment
  • Environment
  • Family
  • Finance
  • Fitness
  • Food
  • General
  • Health
  • Home
  • Legal
  • Lifestyle
  • Marketing
  • Music
  • Pets
  • Photography
  • Real Estate
  • Shopping
  • Tech
  • Travel
  • Web Design